Every time interval, the thread referenced above in the engine will also ask the SL5KServer to perform a save.
Rslogix Emulate 5000 V30 Download Program ToWhen I try to download program to ABVBP-1, Virtual Chassis, I can not download because There is an error message Error: Controller not in correct mode.![]() I read a Tech Note on Rockwells site that told me to delete and then recreate the RSLinx ABVPB-1 Virtual Backplane driver. If these methods you suggested can fix this problem, I will tell to everyone immediately. Theres a method involving deleting your VBP in linx, restarting stuff in a certain order, etc etc. CTRL-ALT-DELETE. (Bring up the task manager, if it does not come up with C-A-D). ![]() Then you should be able to remove the stuck processor from your VBP rack in the chassis monitor. I tried removing and replacing the processor as instructed here, and it didnt clear my fault. What finally cleared it for me was pressing clear fault in the minor fault tab of the controller properties in RSLogix 5000. Also, for anyone out there who wants to know the details of this error, heres an excerpt from an old tech note: It will help to start with a little background. Under the hood, SoftLogix uses the same software that RSLogix 5000 does to maintain changes made by another workstation. A heartbeat thread in RSLogix 5000 periodically asks the controller if any changes have been logged to the change log. If so, it reads those changes and applies them to the current image. Likewise, in SoftLogix, there is a separate process, the SL5KServer, which has the same thread. The engine communications with its server via IPC and the server communicates to the engine using normal communication protocols via RSLinx. Following download, the SL5KServer opens the image sent to the engine during download and attempts to go online. Similarly, following a power cycle (or pullredrop), the server opens an ACD, downloads it to the engine, and automatically goes online as part of a normal download. Either way, once the controller has an image to run, the SL5KServer should be online. Every 10 seconds, a thread in the engine asks the server if it is still online. If it is not, then the engine turns the battery LED ON (RED) and sends a command to the server to ask it to try to go online. If the battery LED was not already ON, it also logs a battery fault. If communications are just busy, the LED may go RED and then when the comm thread has more time, it may eventually turn green again. This thread checks every 10 seconds even if persistent storage save is disabled, since a save will still occur at powerdown.
0 Comments
Leave a Reply. |
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |